On May 19, 2018, a high-pressure ethylene release and fire at the Kuraray America EVAL resin plant in Pasadena, Texas, injured 21 workers. EVAL Reactor 2 was being restarted after a maintenance outage when a pressure safety valve (PSV) activated, releasing approximately 2,300 pounds of high-pressure ethylene through a discharge line terminating in an open area where contractor workers were present.
The ethylene ignited, causing a flash fire that burned contractors positioned near the PSV discharge location. The CSB found that startup procedures did not adequately control conditions to prevent PSV activation, that the PSV discharge routed ethylene to an unsafe location, and that contractors were not warned of the potential for a high-pressure ethylene release.
The December 2022 CSB report issued 12 recommendations to Kuraray America. Eleven were closed at time of report; one remained open. Recommendations focused on startup procedures, PSV discharge system design, and contractor safety.