On May 3, 2019, an explosion and fire at the AB Specialty Silicones chemical manufacturing facility in Waukegan, Illinois, killed four workers and destroyed the production building. An operator inadvertently added an incompatible chemical to a batch reaction tank from a visually identical drum differentiated only by a small label. The addition triggered an uncontrolled reaction generating hydrogen gas inside the building, which accumulated to flammable concentration and ignited.
The CSB found that AB Specialty Silicones was not regulated under OSHA PSM because the chemicals used were below threshold quantities — a regulatory gap allowing the facility to operate without hazard analysis, procedure requirements, and safeguards that might have prevented the incident. The facility had no formal reactive hazard management program, no PHA, and no engineering controls to prevent incompatible chemical mixing or detect accumulated hydrogen.
The September 2021 CSB report issued 3 recommendations, all to AB Specialty Silicones, all closed, focused on reactive hazard identification, chemical storage and labeling, and engineering controls to prevent hydrogen accumulation.