On December 19, 2007, a runaway chemical reaction and explosion at T2 Laboratories in Jacksonville, Florida, killed four workers, injured 32 others — including four members of the public — and leveled the facility. The explosion was felt miles away and shattered windows in the surrounding industrial park.
T2 Laboratories was producing MCMT (methylcyclopentadienyl manganese tricarbonyl), a gasoline additive, in a 2,450-gallon jacketed reactor. The synthesis involves an exothermic reaction between sodium and methylcyclopentadiene in a solvent. On the day of the incident, the cooling system failed to control the reaction heat, and the temperature rose beyond control. A runaway reaction followed, rapidly generating hydrogen gas and increasing pressure until the reactor catastrophically exploded.
The CSB found that T2 had never conducted a formal reactive hazard assessment for the MCMT synthesis process. The company was unaware that a cooling failure during the reaction could lead to a runaway decomposition that generates hydrogen gas — an uncontrolled exotherm that was entirely foreseeable with adequate reactive hazard analysis.
This incident traced to breakdowns across 4 PSM elements (PHA · PSI · SOP · MI). Each represents a documented gap that process safety documentation and consulting can close before a similar event occurs at your facility.