On July 27, 2021, two contract employees were fatally injured and 30 others were transported to medical facilities following a massive release of approximately 100,000 pounds of hot acetic acid at the LyondellBasell facility in La Porte, Texas. Contract workers from Turn2 Specialty Companies were removing what they believed to be a non-pressure-retaining gearbox from a plug valve — but instead removed the pressure-retaining bonnet bolts, causing a catastrophic release of hot acetic acid (approximately 225°F) under full process pressure.
The CSB found that plug valve design is inherently ambiguous: pressure-retaining and non-pressure-retaining fasteners look nearly identical on many designs. No equipment-specific written procedure was provided to the contractors for this work, contractor oversight by LyondellBasell was inadequate, and the contractors had not been trained on the specific plug valve design. This incident exposed systemic weaknesses in contractor management and plug valve safety across the industry.
This incident traced to breakdowns across 1 PSM element (PHA). Each represents a documented gap that process safety documentation and consulting can close before a similar event occurs at your facility.