On September 14, 2020, a thermal decomposition event at the Bio-Lab Inc. pool chemical manufacturing facility in Conyers, Georgia, resulted in the release of toxic chlorine gas. The company manufactures pool and spa treatment products containing chlorine-based compounds (sodium dichloroisocyanurate, or NaDCC). No injuries were reported; however, Interstate Highway 20 was temporarily closed due to the smoke and toxic gas produced by the decomposing pool chemicals.
The CSB's investigation of the Conyers incident was combined with the Bio-Lab Lake Charles incident (CS-020) and produced a joint final report in April 2023. The combined investigation found that chlorinated pool chemicals — when exposed to heat, water, or contamination — can undergo rapid exothermic decomposition producing toxic chlorine gas and significant fire risk, creating serious community hazards even without worker casualties.
This incident traced to breakdowns across 1 PSM element (PHA). Each represents a documented gap that process safety documentation and consulting can close before a similar event occurs at your facility.