On August 27, 2020, Hurricane Laura — a Category 4 storm — struck the Bio-Lab pool chemical manufacturing facility in Westlake, Louisiana. The hurricane damaged the facility's roof and walls, allowing rainwater to contact trichloroisocyanuric acid (TCCA, a pool sanitizer), triggering exothermic decomposition, fire, and the release of toxic chlorine gas. There were no injuries, but significant facility damage occurred. The fire burned for days and released toxic gas into the surrounding community.
The CSB found that Bio-Lab's building structures were not designed or maintained to withstand hurricane-force winds; fire protection systems were non-functional when needed; open process hazard analysis (PHA) action items had not been implemented; and the facility had no adequate hurricane preparedness plan for protecting reactive chemical inventories. The incident highlighted the growing risk of natural hazard-triggered chemical incidents (NaTech events).
This incident traced to breakdowns across 1 PSM element (PHA). Each represents a documented gap that process safety documentation and consulting can close before a similar event occurs at your facility.