On July 17, 2007, explosions and fire erupted in the outdoor tank storage area at Barton Solvents in Valley Center, Kansas. Approximately 6,000 residents were evacuated. There were no fatalities or serious injuries, but the facility sustained extensive damage. Barton Solvents packages, stores, and distributes solvents and chemical products.
A tanker truck was offloading VM&P naphtha (a nonconductive flammable liquid) into a 15,000-gallon storage tank when the incident occurred. The CSB determined that a static spark ignited the air-vapor mixture inside the tank. The spark most likely originated from a metal float used to measure liquid level — as the tank was filled, the float oscillated and generated a static discharge sufficient to ignite the vapor-air mixture.
The CSB investigation highlighted a broadly misunderstood hazard: nonconductive flammable liquids can accumulate static charge during transfer and are more prone to static-ignition events than conductive liquids. MSDSs at the time did not adequately address this hazard, and industry awareness was insufficient.
This incident traced to breakdowns across 4 PSM elements (PSI · SOP · EAP · MI). Each represents a documented gap that process safety documentation and consulting can close before a similar event occurs at your facility.