On January 13, 2003, a vapor cloud fire erupted at the BLSR Operating oilfield waste disposal facility near Rosharon, Texas, south of Houston. Two vacuum trucks were delivering flammable gas condensate waste for disposal. Two BLSR employees and one truck driver were fatally burned, and four other workers suffered serious burns.
The CSB found a lack of hazard recognition and unsafe handling of flammable liquids. Waste liquids removed from crude and condensate tanks can contain enough hydrocarbons to be flammable, but they were not identified that way. Unloading onto an open concrete pad generated flammable vapor, and diesel truck engines exposed to flammable vapor can overspeed and cannot be shut off normally.
The CSB approved its final report on September 17, 2003, with 18 recommendations.
Full recommendation text and current status: CSB investigation page.
This incident involved breakdowns across 4 PSM-related areas (PSI · SOP · TRN · EAP). Each represents a gap that process safety programs are designed to close.