On January 25, 2005, a gas explosion killed three workers at the Acetylene Service Company plant in Perth Amboy, New Jersey. The blast originated in a wooden shed near six large storage tanks that received liquid waste from the plant's acetylene generating system.
The CSB's Safety Bulletin, Dangers of Flammable Gas Accumulation, found that a check valve did not prevent acetylene from flowing back through the generator water lines. The CSB recommended better isolation of those lines, such as double block and bleed with a vent to a safe location, and an effective PSM program with procedures workers understand.
The bulletin was released January 26, 2006, with 5 recommendations.
Full recommendation text and current status: CSB investigation page.
This incident involved breakdowns across 4 PSM-related areas (SOP · MI · TRN · PSI). Each represents a gap that process safety programs are designed to close.